Nov 28, 2010 For a Panasonic microwave (model NN-SN667), I don't find in the manual a chart or more specific information about how I choose the 'desired food number' for the sensor cook feature. The instructions say to press 1 - 9 'until the desired food number. Mar 16, 2019 Shop Panasonic NE-1054F Stainless Steel Commercial Microwave Oven - 120V, 1000W. Unbeatable prices and exceptional customer service from WebstaurantStore. Find many great new & used options and get the best deals for Panasonic NN-SA651S 1.2 cu. Microwave Oven with Inverter Technology at the best online prices at. Browse Panasonic Microwave Ovens. Our website uses cookies and similar tools to improve its performance and enhance your user experience. By continuing to use this website without changing your settings you consent to their use. Mid-Size Genius ® Inverter ® Stainless Steel Finish Microwave Oven. Nov 20, 2014 HOW TO CHANGE BULB ON PANASONIC MICROWAVE OVENS Sports Cover24/7. Panasonic Inverter Microwave Oven Repair - Duration. Easy Microwave Oven Lamp Replacement.
Some microwaves have built in fault codes to help us determine what may be wrong when the microwave has a problem....
Newer Panasonic Microwaves have built in fault codes....
they look like H97, H98....
Panasonic Countertop Microwave Oven 1250w
Troubleshooting of Inverter Circuit (U) and Magnetron
This oven is programmed with a self diagnostics failure code system which will help for troubleshooting, H97, H98 and H99 are the provided failure magnetron and inverter circuit problem areas. This section explains failure codes of H97, H98 and H99. H97, H98 and H99 appears in display window a short time after start key is pressed and there is no microwave oscillation.
NOTE:
DO NOT try to REPAIR this Inverter Power Supply (U) and also DO NOT RE-ADJUST PRESET VOLUME on the board. It is very dangerous to repair or adjust without sufficient test equipment because this circuit handles very high voltage and very large current. Off alignment or inverter board operation is dangerous. Operating a misaligned inverter circuit is dangerous due to the very high voltage and current that is produced by this board. Defective boards must be replaced with a new one.
- Check magnetron filament for open or short to casing before proceeding to determine a good magnetron.
Alternative way to troubleshoot oven with AC Ampere meter used.
H97, H98 and H99 appears in display window a short time alter start key is pressed and no microwave oscillation with AC Ampere meter used for troubleshooting.
NOTE:
DO NOT try to REPAIR this Inverter Power Supply (U) and also DO NOT RE-ADJUST PRESET VOLUME on the board. It is very dangerous to repair or adjust without sufficient test equipment because this circuit handles very high voltage and very large current. Off alignment or inverter board operation is dangerous. Operating a misaligned inverter circuit is dangerous due to the very high voltage and current that is produced by this board. Defective boards must be replaced with a new one.
- Check magnetron filament for open or short to casing before proceeding to determine a good magnetron.
Frigidaire also has some built in fault codes for there microwaves....
they look like F3, F4....
PROBLEM: Diagnosis and Fault Codes for the FMT148GP, FMT148GI, FMT144GI, and FMB136GI that have this feature. ( there may be others )
SOLUTION: The following information is a guide for Sensor Quick Test Sensor Cooking Diagnosis, Fault 'F' Codes and Gas/Humidity sensor detection test.
SENSOR QUICK TEST SENSOR COOKING DIAGNOSIS
Simultaneously touch and hold keypads 7 & 8 and record the number showing in the display
- If the number showing is between 15 and 185 then the reading is more than likely normal; however you need to go one step further and verify by performing a 'SENSOR DETECTOR TEST'
- If the number showing in the display is higher than 213 you more than likely have on of the following problems; sensor failed open, sensor unplugged, wiring, or smart board.
- If the number showing in the display is less than 6 you more than likely have s shorted sensor, or a defective board.
FAULT 'F' CODES SENSOR SELF DIAGNOSTICS
Panasonic Microwaves Countertop Nn Sa651s
F0 Humidity sensor program (open or shorted) at the start of cooking program. Press keypads 7 & 8 simultaneously and read sensor value showing in the display. Compare the sensor 'Quick Test' values to determine is there a problem.
F3 Shorted key panel (keypad/panel shorted for a period of over 60 seconds). You can test this feature by holding in one of the keypads for over 60 seconds - F3 will display.
F4 Open humidity sensor during cooking process. Sensor was open for a period of over 60 seconds during the cooking process.
F5 Shorted humidity sensor during cooking process. Sensor was shorted for a period of over 5 seconds during the cooking process.
GAS/HUMIDITY SENSOR DETECTION TEST
The Gas/Humidity sensor detects both humidity (steam) and hydrocarbons (food odors) during sensor cooking modes.
- Place a 1/3 cup of hot water in the center of the microwave oven.
- Push the 'VEGETABLE' pad of the key panel ('FRESH VEGGIES: will scroll across the display).
- Push 'START'
- Simultaneously touch keypads 7 & 8 and record diagnostic numbers in the display (example: 42)
- The unit will begin heating the water and will display 'FRESH-VG', until it reaches humidity 'detection'. When humidity 'detection' occurs, the control will beep and begin counting down. At the end of the cycle the control will beep and oven will shut off.
- Touch CLEAR/OFF
NOTE:
If you successfully complete steps 1 through 6 with no problems, then the humidity sensor is operating normally; however, if you encountered a problem during this test (TEST FAILED), then suspect a problem in the sensor circuit (sensor , sensor wiring/connection, control smart board).
NOTE:
Testing the sensor with an ohm meter can damage the sensor. The only portion of the sensor that should be tested with a meter is the heater. (Pins 3 & 4)
Heater resistance- approx. 30 ohms
GE also has some built in fault codes for there Microwaves....
They look like F1, F2....
F1 - ( open thermal sensor ), will occur below 190ºF of cavity temperature within 15 minutes of starting convection, combination or roast cook.
Panasonic Microwave Inverter Countertop
F2 - ( shorted thermal sensor ), will occur if a shorted thermal sensor is detected continuously over 5 seconds on convection, combination or roast cooking.
NOTE: it will take a minimum of 5 minutes of convection run time before F1 or F2 code will be displayed if the thermal sensor is shorted/open.
F3 - ( shorted key panel ), will occur if a shorted key panel is detected continuously over 60 seconds.
NOTE: It will take a minimum of 1 minute of run time before the F code will be displayed.
F4 ( open humidity sensor ), will occur if humidity sensor is detected as being open continuously over 5 seconds.
F5 - ( shorted humidity sensor ), will occur if humidity sensor is detected as being shorted continuously over 5 seconds.
NOTE: It will will take a minimum of 15 seconds after the magnetron is energized before the F4 or F5 code will be displayed if the humidity sensor is shorted/open. Also the unit must be plugged into a 120 volt outlet for at least 5 minutes before sensor is checked, this also applies after the humidity sensor has been changed. Before checking operation of new sensor allow init to be plugged in for at least 5 minutes.
F6 - ( shorted temperature probe ), will occur if temperature probe is detected as being open or not plugged into the receptacle. If probe is plugged in and 'ProbE' is on display, check probe for continuity with ohm meter.
NOTE: This 'F' code and 'ProbE' will happen immediately if probe is shorted/open.
TOUCH PANEL & MICROCOMPUTER BOARD TEST FOR WHIRLPOOL....
The microwave oven may be provided with a self diagnostic routine that can be operated
through the touch pad keyboard. To enter the self-diagnostic routine:
- While pressing the CANCEL keypad:
a) Open the oven door.
b) Unplug the microwave oven for 2-seconds and plug it back in.
c) Release the CANCEL keypad and close the oven door. You will see the following display.
CHART
NOTE: The humidity sensor test results will appear on the display after 8-seconds.If the tests are successful, 'OK ' will be displayed. If one or more of the tests fail, 'ERR ' will be displayed.. 2.When a keypad is pressed, a number according to the test chart will be displayed. When no keypad is pressed, a blank '—' is displayed...
POWER FAILURE & FAILURE CODES
Power Failure: After a power failure, the WELCOME screen will be displayed.
F2 —Keyboard Failure: Refer to the Tech Sheet and conduct a touch panel continuity test.
F3H —Humidity Sensor Failure: Refer to the Tech Sheet and test the sensor.
F6 —Microwave Relay Failure: Check the microwave relay.
F7 —Microcomputer Board Failure: Change the microcomputer board.
Sharp commercial grade microwave codes....
EE Mode | Reason | Action Required |
EE 1, EE 2 | Magnetron failure | Call for service* |
EE 3 | Both magnetrons failed | Call for service. |
EE 4 R-23GT, R-24GT and R-25JT only | Voltage too high | Follow instructions on page 5 of Operation Manual under VOLTAGE SELECT to change from 208V to 230V. If problem is not corrected, call an electrician. |
EE 5 R-23GT, R-24GT and R-25JT only | Voltage too low | Follow instructions on page 5 of Operation Manual under VOLTAGE SELECT to change from 230V to 208V. If problem is not corrected, call an electrician. |
EE 6, EE10, EE16 | Thermistors failure | Call for service. |
EE 7 | Exhaust air temperature too high | Check that nothing is blocking air intake openings on oven back or that oven exterior is very hot. Correct. Wait a few minutes and try again. If problem persists, call for service. |
EE 8 | Circuit failure | Call for service. |
EE 9 | Maximum time is exceeded | Check page 11 in the Operation Manual. Touch STOP/CLEAR pad, and reprogram correctly. |
EE 0 | Fan lock error | Call for service. |
EE17 | Magnetron temperature too high | Touch STOP/CLEAR pad. Wait a few minutes and try again. If problem persists, call for service. |
* EE 1 and EE 2: Can continue to use oven before service; however, check food carefully as additional cooking time will be needed.
Any time the EE is flashing, the servicer should be called. When EE is not flashing, check the reason and correct. Service is not necessary.
F1 - Thermistor open - No heat or thermistor sensing error.
F2 - Thermistor short for cooking - No heat in 10 seconds after cooking starts.
F3 - Thermistor short after cooking - Thermistor temp does not go down after cooking ends.
F4 - sensor open - Humidity sensor sensing error.
F5 - Damper switch sensing error.